*Testing flow rate |
45L/H |
Recovery rate |
4% |
*Suggested to use flow rate |
25L/H |
Power |
1.9KW |
Applicable power |
AC220V, 50Hz |
Working temperature |
5-45℃ |
Inlet water TDS |
<45000ppm |
Freshwater TDS |
<600ppm |
Design pressure |
1000PSI |
Working pressure |
≤850PSI |
Inlet water residual chlorine |
<0.1ppm |
Inlet water SDI |
<5 |
Machine net size |
64*50*55 (cm) |
Machine net weight |
60KG |
YOUBER Portable Seawater Desalination Machine Process Flow
YB-SWRO-500LPD Portable Seawater Desalination Machine Technical Parameter
Note:
* is based on the below testing conditions: 32000ppm NaCl, 800psi (5.5MPa), 77°F (25℃), PH is 8, less than relevant recovery rate (variation range no more than -15%);
* Based on the below reasons: different seawater quality in every place, bad seawater quality and bad equipment usage environment, complicated seawater composition, we suggest customer to use “suggested flux”, which can protect the equipment service life;
YB-SWRO-500LPD Portable Seawater Desalination Machine Main configuration
Consumable replacement cycle:
1.5 micron PP filter and 1micron pleated filter : about 3 months
2.Carbon filter: about 6 months
3.UV lamp: about 9000hours, one year.
4.USA DOW RO membrane: about 3 years
Note:the premise of calculation of above replacement cycle is on the basis of satisfying the use and maintenance condition of this equipment, running 20 hours per day
1. Can be used for ships, fishing boats, yachts, marine, navy drinking water use
2. Can be used for island family, island restaurant, seaside villa, resort drinking water use.
3. Can be used for salty alkali lake drinking water use.
4. Can be used for desert underground water.